Over the years the Oriel bay had become detached from the main
building. The internal walls of the bay were finished with oak
panelling along with ornate plaster works, all of which were protected
by listing in their own right.
Action Wall Ties operatives diamond drilled 30mm diameter holes approximately 3.8Metre in depth and a second hole angled off approximately 1 Metre into the masonry to meet and form cross ties to each side of the bay window at five levels. They then prepared for, supplied and inflated the Cintec sock anchors in accordance with the specifications and manufacture’s recommendations by AWT Cintec certifed operatives .